Aroclor 1242 Properties

Boiling point 325-366 °C
Density 1.381-1.392 g/cm3(Temp: 25 °C)
vapor pressure 10 at 37.8 °C (calculated, Monsanto, 1960)
Flash point -12 °C
storage temp. room temp
solubility (wt %):
Benzoic acid (10.0 at 31 °C), pyridine (132.5 at 30 °C), diglycol monoethyl ether (224 at 31 °C), methanol (42.5 at 29 °C), ethanol (23.3 at 29 °C) (Monsanto, 1960)
form Straw-colored liquid
Water Solubility 277ug/L(20 ºC)
Henry's Law Constant 0.347, 0.575, 0.928, 1.47, 2.27, 3.43, 5.09, 7.60, and 10.8 at 0.0, 5.0, 10.0, 15.0, 20.0, 25.0, 30.0, 35.5, and 40.0 °C, respectively (predicted, Burkhard et al., 1985)
Exposure limits Potential occupational carcinogen. NIOSH REL: TWA 1.0 g/m3, IDLH 5 mg/m3; OSHA PEL: TWA 1 mg/m3; ACGIH TLV: TWA 1 mg/m3 (adopted).
EPA Substance Registry System Aroclor 1242 (53469-21-9)

SAFETY

Risk and Safety Statements

Symbol(GHS) 
GHS02,GHS06,GHS08,GHS09,GHS07
Signal word  Danger
Hazard statements  H225-H304-H315-H336-H373-H410-H350-H412-H301+H311+H331-H370-H361f-H411
Precautionary statements  P210-P260-P301+P310-P331-P370+P378-P403+P235-P201-P280-P308+P313-P302+P352+P312-P304+P340+P312-P403+P233-P261-P273-P281-P311
Hazard Codes  F,Xn,N,Xi,T
Risk Statements  11-38-50/53-65-67-33-36/37/38-22-62-51/53-48/20-39/23/24/25-23/24/25-52/53-45
Safety Statements  9-16-29-33-60-61-62-35-36-26-36/37-45-53
RIDADR  2315
OEB E
OEL TWA: 0.001 mg/m3 [*Note: The REL also applies to other PCBs.]
WGK Germany  3
RTECS  TQ1356000
HazardClass  9
PackingGroup  II
Toxicity Acute oral LD50 for rats 4,250 mg/kg (quoted, RTECS, 1985).
IDLA 5 mg/m3
NFPA 704
1
2 0

Aroclor 1242 price More Price(4)

Manufacturer Product number Product description CAS number Packaging Price Updated Buy
Sigma-Aldrich(India) 48732 Aroclor 1242 solution certified reference material, 50?mg/kg in transformer oil 53469-21-9 5ML ₹11118.8 2022-06-14 Buy
Sigma-Aldrich(India) 48731 Aroclor 1242 solution certified reference material, 500?mg/kg in transformer oil 53469-21-9 5ML ₹14763 2022-06-14 Buy
Sigma-Aldrich(India) 48706 Aroclor 1242 solution certified reference material, 200?μg/mL in methanol 53469-21-9 1ML ₹3830.4 2022-06-14 Buy
Sigma-Aldrich(India) 44806 Aroclor 1242 solution certified reference material, 1000?μg/mL in isooctane 53469-21-9 1ML ₹5692.4 2022-06-14 Buy
Product number Packaging Price Buy
48732 5ML ₹11118.8 Buy
48731 5ML ₹14763 Buy
48706 1ML ₹3830.4 Buy
44806 1ML ₹5692.4 Buy

Aroclor 1242 Chemical Properties,Uses,Production

Chemical Properties

Clear; mobile liquid; approximately 3.1 chlorine atoms per molecule.

Physical properties

Colorless to light yellow, viscous, oily, dense, nonflammable liquid with a weak, hydrocarbon or aromatic-type odor

Uses

Dielectric liquids; in fixed paper capacitors; heat-transfer liquid widely used in transformers and utility transmission lines; swelling agents for transmission seals; ingredient in lubricants, oils, and greases; plasticizers for cellulose products, vinyl, and chlorinated rubbers; in polyvinyl acetate to improve fiber-tear properties. In fluorescent and high-intensity discharge ballasts manufactured prior to 1979 (U.S. EPA, 1998) and in electric motors (Monsanto, 1960).
Prior to being banned in 1976, PCB-1254 was used in home appliances including air conditioners, furnaces, washers, and driers. May have been added to automotive transmission oils to swell shrunken transmission seals in place (Monsanto, 1960).
At a concentration of 5 to 25 wt %, increased the effective kill-life of the lindane spray up to 10 times. May have been used in chlordane and BHC insecticide formulations. In polyvinyl acetate emsulsions to impart strong bonding power in adhesives. In various nitrocellulose lacquers to impart weather resistance, luster, adhesion, and decreased burning rate. These lacquers may also contain tricresyl phosphate (Monsanto, 1960).

General Description

Viscous oily liquid.

Air & Water Reactions

Insoluble in water.

Reactivity Profile

Simple aromatic halogenated organic compounds are very unreactive. Reactivity generally decreases with increased degree of substitution of halogen for hydrogen atoms.

Health Hazard

Chlorodiphenyl, 42% chlorine (one of over 200 possible chlorinated compounds that comprise polychlorinated biphenyls or PCBs) is an irritant of the eyes and mucous membranes, is toxic to the liver, and causes an acneform dermatitis (chloracne). It is a liver carcinogen in animals.

Fire Hazard

Some may burn but none ignite readily. Containers may explode when heated. Some may be transported hot.

Safety Profile

Suspected human carcinogen. Poison by subcutaneous route. Mildly toxic by ingestion. Human systemic effects by inhalation: pulmonary and liver effects. Experimental reproductive effects. Mutation data reported. When heated to decomposition it emits toxic fumes of Cl-. Used in heat transfer, hydraulic fluids, lubricants, and insecticides. See also POLYCHLORINATED BIPHENYLS.

Carcinogenicity

The genotoxicity of PCBs has been tested in in vivo and in vitro studies with generally negative results.

Environmental Fate

Biological. A strain of Alcaligenes eutrophus degraded 81% of the congeners by dechlorination under anaerobic conditions (Bedard et al., 1987). A bacterial culture isolated from Hamilton Harbour, Ontario was capable of degrading a commercial mixture of PCB-1242. The metabolites identified by GC/MS included isohexane, isooctane, ethylbenzene, isoheptane, isopropylbenzene, n-propylbenzene, isobutylbenzene, n-butylbenzene, and isononane (Kaiser and Wong, 1974). A strain of Pseudomonas, isolated from activated sludge and grown with biphenyl as the sole carbon source, degraded 2,4′-dichlorobiphenyl yielding the following compounds: two monochlorobenzoic acids, two monohydroxydichlorobiphenyls, and a yellow hydroxyoxo(chlorophenyl) chlorohexadienoic acid. Irradiation of the mixture containing these compounds led to the formation of two monochloroacetophenones and the disappearance of the yellow compound. Similar compounds were found when 2,4′-dichlorobiphenyl was replaced with a PCB-1242 mixture (Baxter and Sutherland, 1984).
Soil. In Hudson River, NY sediments, the presence of adsorbed PCB-1242 in core samples suggests it is very persistent in this environment. The estimated half-life ranged from 1.3 to 2.1 yr (Bopp et al., 1982).
Photolytic. PCB-1242 in a 90% acetonitrile/water solution containing 0.2 to 0.3 M sodium borohydride and irradiated with UV light (λ = 254 nm) reacted to yield dechlorinated biphenyls. Without sodium borohydride, the reaction proceeded much more slowly (Epling et al., 1988).
Chemical/Physical. When PCB-1242-contaminated sand was treated with a poly(ethylene glycol)/potassium hydroxide mixture at room temperature, 27% reacted after 2 wk forming aryl poly(ethylene glycols) (Brunelle and Singleton, 1985).

Aroclor 1242 Preparation Products And Raw materials

Raw materials

Preparation Products

Aroclor 1242 Suppliers

Global( 24)Suppliers
Supplier Tel Country ProdList Advantage Inquiry
CLEARSYNTH LABS LTD. +91-22-45045900 Hyderabad, India 6351 58 Inquiry
Aladdin Scientific +1-+1(833)-552-7181 United States 57511 58 Inquiry
Shanghai Aladdin Bio-Chem Technology Co.,LTD 400-400-6206333 18521732826 China 25014 65 Inquiry
Shanghai Aladdin Biochemical Technology Co.,Ltd. +86-18521732826 China 48467 58 Inquiry
A.P.T. Labs, Inc. 610-375-3888 United States 304 42 Inquiry
TCI (Shanghai) Chemical Trading Co., Ltd. 021-021-61109150 China 31163 58 Inquiry
Shanghai Bikai Technology Co. , Ltd. 18516304666 China 3101 58 Inquiry
Hubei Qifei Pharmaceutical Chemical Co., Ltd 027-59322506 18071128681 China 9978 58 Inquiry
Hubei DAHAO Chemical Co., Ltd. 027-59106191 13986034860 China 9894 58 Inquiry
ShangHai Anpel Co, Ltd. 18501792038; 18501792038 China 9614 58 Inquiry
aroclor 1242 reference standard for clp [40cfr136(1986)]pcb-1242 chloriertebiphenyle,chlorgehalt42% chlorodiphenyl(42%chlorine) chlorodiphenyl(42%cl) clorodifenili,cloro42% diphenylechlore,42%dechlore gechloreerdedifenyl polychlorinatedbiphenyl(aroclor1242) polychlorinatedbiphenyl1242 AROCLOR 1242, 1X1ML, ISO, 1UG/ML AROCLOR 1242, 1X1ML, HEXANE 1000UG/ML AROCLOR 1242, 1X1ML, MEOH, 200UG/ML AROCLOR 1242, 1X1ML, ISO, 1000UG/ML AROCLOR 1242, 1X5ML, TRANSFORMER OIL, 50 0MG/KG AROCLOR 1242, 1X5ML, TRANSFORMER OIL, 50 MG/KG AROCLOR 1242, 50MG, NEAT aroclor 1242 solution aroclor 1242, 42 perc.cl, pcb c12h8cl2 and c12h7cl3 and c12h6cl4 PCB Aroclor 1242 Polychlorinated biphenyl (42% Cl) Arochlor 1242 100mg [53469-21-9] Aroclor 1242 (PCB 1242) SILVER STAND 1,2-dichloro-3-(2,4-dichlorophenyl)benzene PCB Aroclor 1242 @1000 μg/mL in Isooctane Aroclor 1242@1000 μg/mL in Hexane Aroclor 1242@50 ppm in Transformer oil PCB Aroclor 1242 @3.0 mg/mL in Isooctane Aroclor 1242 @100 μg/mL in MeOH Aroclor 1242 @1000 μg/mL in MeOH Aroclor 1242 @35 μg/mL in MeOH Aroclor 1242@35 μg/mL in Isooctane Aroclor 1242@500 ppm w/w in Transformer oil AROCLOR 1242 53469-21-9 PCBC12H8CI2ANDC12H7CI3ANDC12H6CI4 OLM04 Statement of WorkEnvironmental Standards Separate Source Standards Single Component Solutions AroclorsEnvironmental Standards Volatiles/ Semivolatiles Environmental Standards AR to AZEnvironmental Standards Aroclors, PCBs, and Dioxins AroclorsMethod Specific 2000/60/EC A Alphabetic European Community: ISO and DIN 8000 Series Solidwaste Methods AroclorsEPA CLP Standards Method 8082EPA