Product Identification | Back to Contents | 【Product Name】
Resorcinol dimethyl ether | 【Synonyms】
3-Methoxyanisole m-Dimethoxybenzene m-Methoxyanisole Resorcinol dimethyl ether | 【CAS】
151-10-0 | 【Formula】
C8H10O2 | 【Molecular Weight】
138.16999999999999 | 【EINECS】
205-783-4 | 【RTECS】
CZ6474000 | 【RTECS Class】
Drug | 【Beilstein/Gmelin】
878582 | 【Beilstein Reference】
4-06-00-05663 |
Physical and Chemical Properties | Back to Contents | 【Appearance】
Colorless liquid. | 【Solubility in water】
Slightly soluble | 【Melting Point】
-52 | 【Boiling Point】
218 | 【Vapor Pressure】
0.2 (25 C) | 【Density】
1.05 g/cm3 | 【Partition Coefficient】
1.93 | 【Heat Of Vaporization】
43.5 kJ/mol | 【Heat Of Combustion】
-4283 kJ/mol | 【Vapor Density】
4.76 | 【Refractive Index】
1.5231 (20 C) |
First Aid Measures | Back to Contents | 【Ingestion】
Do NOT induce vomiting. If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical aid. | 【Inhalation】
Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid. | 【Skin】
Get medical aid. Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse. | 【Eyes】
Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid. |
Handling and Storage | Back to Contents | 【Storage】
Keep away from heat, sparks, and flame. Keep away from sources of ignition. Store in a tightly closed container. Store in a cool, dry, well-ventilated area away from incompatible substances. | 【Handling】
Wash thoroughly after handling. Remove contaminated clothing and wash before reuse. Use only in a well ventilated area. Avoid contact with eyes, skin, and clothing. Empty containers retain product residue, (liquid and/or vapor), and can be dangerous. Keep container tightly closed. Avoid contact with heat, sparks and flame. Avoid ingestion and inhalation. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose empty containers to heat, sparks or open flames. |
Hazards Identification | Back to Contents | 【Inhalation】
Causes respiratory tract irritation. The toxicological properties of this substance have not been fully investigated. Can produce delayed pulmonary edema. Inhalation at high concentrations may cause CNS depression and asphixiation. | 【Skin】
Causes skin irritation. May cause cyanosis of the extremities. | 【Eyes】
Causes eye irritation. May cause chemical conjunctivitis and corneal damage. | 【Ingestion】
May cause gastrointestinal irritation with nausea, vomiting and diarrhea. The toxicological properties of this substance have not been fully investigated. | 【EC Risk Phrase】
R 21 | 【EC Safety Phrase】
S 36/37 |
Exposure Controls/Personal Protection | Back to Contents | 【Personal Protection】
Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin: Wear appropriate protective gloves to prevent skin exposure. Clothing: Wear appropriate protective clothing to prevent skin exposure. | 【Respirators】
A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2 requirements or European Standard EN 149 must be followed whenever workplace conditions warrant a respirator's use. | 【Exposure Effects】
Prolonged or repeated skin contact may cause dermatitis. Effects may be delayed. |
Fire Fighting Measures | Back to Contents | 【Flash Point】
88 | 【Fire Fighting】
Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Use water spray to keep fire-exposed containers cool. Combustible Liquid. To extinguish fire, use water, dry chemical, chemical foam, or alcohol-resistant foam. Use water spray to cool fire-exposed containers. Use agent most appropriate to extinguish fire. |
Accidental Release Measures | Back to Contents | 【Small spills/leaks】
Absorb spill with inert material, (e.g., dry sand or earth), then place into a chemical waste container. Avoid runoff into storm sewers and ditches which lead to waterways. Clean up spills immediately, using the appropriate protective equipment. Scoop up with a nonsparking tool, then place into a suitable container for disposal. Remove all sources of ignition. Use a spark-proof tool. Provide ventilation. |
Stability and Reactivity | Back to Contents | 【Disposal Code】
1 | 【Stability】
Stable at room temperature in closed containers under normal storage and handling conditions. | 【Incompatibilities】
Strong oxidizing agents. | 【Decomposition】
Carbon monoxide, irritating and toxic fumes and gases, carbon dioxide. |
|
Company Name: |
HUAIAN DEPON CHEMICAL CO., LTD. |
Tel: |
0517-82332538 13852381548 |
Fax: |
0517-82332537 |
WebSite: |
https://www.chemicalbook.com/ShowSupplierProductsList1830226/0.htm |
Company Name: |
J & K SCIENTIFIC LTD. |
Tel: |
010-82848833 400-666-7788 |
Fax: |
86-10-82849933 |
WebSite: |
http://www.jkchemical.com |
Company Name: |
Alfa Aesar |
Tel: |
400-6106006 |
Fax: |
021-67582001/03/05 |
WebSite: |
http://chemicals.thermofisher.cn |
|