Product Identification | Back to Contents | 【Product Name】
Fyrol FR 2 | 【Synonyms】
1,3-Dichloro-2-propanol phosphate (3:1) 2-Propanol, 1,3-dichloro-phosphate (3:1) Phosphoric acid tris(1,3-dichloro-2-propyl)ester tris(1,3-Dichloroisopropyl)phosphate tris(1-Chloromethyl-2-chloroethyl)phosphate tris(2-Chloro-1-(chloromethyl)ethyl)phosphate | 【CAS】
13674-87-8 | 【Formula】
C9H15Cl6O4P | 【Molecular Weight】
430.91 | 【EINECS】
237-159-2 | 【RTECS】
UB1473000 | 【RTECS Class】
Tumorigen; Mutagen; Reproductive Effector | 【Merck】
12,4342 | 【Beilstein/Gmelin】
1715458 | 【Beilstein Reference】
3-01-00-01473 |
Physical and Chemical Properties | Back to Contents | 【Appearance】
Clear colorless viscous liquid. Generally a super-cooled liquid at room temperature but may occasionally solidify when held at low temperatures for prolonged periods. | 【Solubility in water】
7 mg/L @ 24 C | 【Boiling Point】
236 | 【Vapor Pressure】
10 | 【Density】
1.5182 g/cm3 (20 C) | 【Partition Coefficient】
3.65 | 【Usage】
Flame retardant formerly used in children's sleepwear, once considered as a potential replacement for tris(2,3-dibromo-1-propyl) phosphate. | 【Refractive Index】
1.4997 (20 C) |
First Aid Measures | Back to Contents | 【Ingestion】
DO NOT INDUCE VOMITING. If the victim is conscious and not convulsing, administer a slurry of activated charcoal in water and simultaneously call a hospital or poison control center. IMMEDIATELY transport the victim to a hospital. | 【Inhalation】
IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. IMMEDIATELY call a physician and be prepared to transport the victim to a hospital even if no symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used. | 【Skin】
IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. IMMEDIATELY call a hospital or poison control center even if no symptoms (such as redness or irritation) develop. IMMEDIATELY transport the victim to a hospital for treatment after washing the affected areas. | 【Eyes】
First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop. |
Handling and Storage | Back to Contents | 【Storage】
Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage. | 【Handling】
All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood. |
Hazards Identification | Back to Contents | 【Ingestion】
See inhalation. | 【Inhalation】
Symptoms of exposure to this compound may include irritation of the skin and respiratory tract, breathing difficulty and pulmonary edema. | 【Skin】
See inhalation. | 【Eyes】
See inhalation |
Exposure Controls/Personal Protection | Back to Contents | 【Personal Protection】
If Tyvek-type disposable protective clothing is not worn during handling of this chemical, wear disposable Tyvek-type sleeves taped to your gloves. | 【Respirators】
Wear a NIOSH-approved half face respirator equipped with an organic vapor/acid gas cartridge (specific for organic vapors, HCl, acid gas and SO2) with a dust/mist filter. | 【Poison Class】
1* |
Fire Fighting Measures | Back to Contents | 【Autoignition】
512 | 【Fire Fighting】
Fires involving this material can be controlled with a dry chemical, carbon dioxide or Halon extinguisher. A water spray may also be used. | 【Fire Potential】
This chemical is combustible. |
Accidental Release Measures | Back to Contents | 【Small spills/leaks】
If you spill this chemical, FIRST REMOVE ALL SOURCES OF IGNITION. Then, use absorbent paper to pick up all liquid spill material. Your contaminated clothing and absorbent paper should be sealed in a vapor-tight plastic bag for eventual disposal. Solvent wash all contaminated surfaces with 60-70% ethanol followed by washing with a soap and water solution. Do not reenter the contaminated area until the Safety Officer (or other responsible person) has verified that the area has been properly cleaned. |
|
Company Name: |
J & K SCIENTIFIC LTD. |
Tel: |
010-82848833 400-666-7788 |
Fax: |
86-10-82849933 |
WebSite: |