5' | | | C | T | G | A | A | G | N16 | ↓ | | 3' |
3' | | | G | A | C | T | T | C | N14 | ↑ | | 5' |
Thermo Scientific Eco57I (AcuI) restriction enzyme recognizes CTGAAG(16/14)^ sites and cuts best at 37°C in G (+SAM) buffer. See
Reaction Conditions for Restriction Enzymes
for a table of enzyme activity, conditions for double digestion, and heat inactivation for this and other restriction enzymes. Note: Also available as a
FastDigest enzyme
for rapid DNA digestion. Isoschizomers: AcuI.
Thermo Scientific conventional restriction endonucleases are a large collection of high quality restriction enzymes, optimized to work in one of the buffers of the Five Buffer System. In addition, the universal Tango buffer is provided for convenience in double digestions. All of the enzymes exhibit 100% activity in the recommended buffer and reaction conditions. To ensure consistent performance, Thermo Scientific restriction enzyme reaction buffers contain premixed BSA, which enhances the stability of many enzymes and binds contaminants that sent in DNA preparations.
Features• Superior quality—stringent quality control and industry leading manufacturing process
• Convenient color-coded Five Buffer System
• Includes universal Tango buffer for double-digestions
• BSA premixed in reaction buffers
• Wide selection of restriction endonuclease specificities
Applications• Molecular cloning
• Restriction site mapping
• Genotyping
• Southern blotting
• Restriction fragment length polymorphism (RFLP)
• SNP
Note: Eco57I requires only Mg2+ for its activity, but is stimulated by S-adenosylmethionine. 0.01 mM S-adenosylmethionine gives a 100-fold increase in Eco57I activity. Still, complete cleavage of some substrates with Eco57I is difficult to achieve Eco57I concentration is determined by the maximum cleavage level achieved when no change in the fragmentation pattern is observed with further enzyme increase. Low salt, high glycerol (> 5%) concentrations, pH > 8.0 or a large excess of enzyme may result in star activity. Eco57I may remain associated with the cleaved DNA. This may cause DNA band shifting during electrophoresis. To avoid atypical DNA band patterns, use the 6X DNA Loading Dye & SDS Solution for sample preparation or heat the digested DNA in the presence of SDS prior to electrophoresis.For methylation sensitivity, refer to product specifications.
关键字: Eco57I (AcuI) (5 U/μL);分子生物学
北京索莱宝科技有限公司是一家集研发、生产、销售、服务于一体的高科技生物企业。技术推广;技术转让;技术咨询;技术服务;生物试剂技术开发;销售生物试剂盒、实验室专用化学试剂、实验室专用设备、办公用品、化工产品(不含危险化学品)、计算机软件及辅助设备;货物进出口、技术进出口、代理进出口;委托加工生产生物制品、生化制品、化工产品(不含危险化学品);生产生物试剂盒;批发第一类医疗器械、第二类医疗器械;批发第三类医疗器械。