Wear self-contained breathing apparatus for firefighting if necessary.
No data available
HEALTH | 3 | Short exposure could cause serious temporary or moderate residual injury (e.g. liquid hydrogen, sulfuric acid, calcium hypochlorite, hexafluorosilicic acid) | |
FIRE | 2 | Must be moderately heated or exposed to relatively high ambient temperature before ignition can occur and multiple finely divided suspended solids that do not require heating before ignition can occur. Flash point between 37.8 and 93.3 °C (100 and 200 °F). (e.g. diesel fuel, sulfur) | |
REACT | 2 | Undergoes violent chemical change at elevated temperatures and pressures, reacts violently with water, or may form explosive mixtures with water (e.g. white phosphorus, potassium, sodium) | |
SPEC. HAZ. |
Wear respiratory protection. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
For personal protection see section 8.
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Do not flush with water.
For disposal see section 13.
Avoid contact with skin and eyes. Avoid inhalation of vapour or mist.
Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic charge.
For precautions see section 2.2.
Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Store in cool place. Never allow product to get in contact with water during storage.
Store under inert gas. Moisture sensitive.
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling the product.
Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Full contact
Material: Fluorinated rubber
Minimum layer thickness: 0,7 mm Break through time: 480 min
Material tested:Vitoject? (KCL 890 / Aldrich Z677698, Size M)
Splash contact
Material: Nature latex/chloroprene Minimum layer thickness: 0,6 mm Break through time: 30 min
Material tested:Lapren? (KCL 706 / Aldrich Z677558, Size M)
data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Complete suit protecting against chemicals, Flame retardant antistatic protective clothing., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Where risk assessment shows air-purifying respirators are appropriate use a full- face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
No data available
Reacts violently with water.
Stable under recommended storage conditions.
Reacts violently with water.
Heat, flames and sparks. Exposure to moisture
No data available
Hazardous decomposition products formed under fire conditions. - Carbon oxides, Hydrogen chloride gas, silicon oxides
Other decomposition products - No data available In the event of fire: see section 5
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
Possible decomposition products in case of hydrolysis are:
hydrochloric acid
Harmful effect due to pH shift.
Discharge into the environment must be avoided.
Offer surplus and non-recyclable solutions to a licensed disposal company. Waste material must be disposed of in accordance with the Directive on waste 2008/98/EC as well as
other national and local regulations. Leave chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself.
Dispose of as unused product.
ADR/RID: 2986 IMDG: 2986 IATA: 2986
ADR/RID: CHLOROSILANES, CORROSIVE, FLAMMABLE, N.O.S. IMDG: CHLOROSILANES, CORROSIVE, FLAMMABLE, N.O.S.
IATA: Chlorosilanes, corrosive, flammable, n.o.s. Passenger Aircraft: Not permitted for transport
ADR/RID: 8 (3) IMDG: 8 (3) IATA: 8 (3)
ADR/RID: II IMDG: II IATA: II
ADR/RID: no IMDG Marine pollutant: no IATA: no
No data available
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.