Carbon oxides
Wear self-contained breathing apparatus for firefighting if necessary.
Use water spray to cool unopened containers.
HEALTH | 1 | Exposure would cause irritation with only minor residual injury (e.g. acetone, sodium bromate, potassium chloride) | |
FIRE | 2 | Must be moderately heated or exposed to relatively high ambient temperature before ignition can occur and multiple finely divided suspended solids that do not require heating before ignition can occur. Flash point between 37.8 and 93.3 °C (100 and 200 °F). (e.g. diesel fuel, sulfur) | |
REACT | 0 | Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2) | |
SPEC. HAZ. |
Use personal protective equipment. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in low areas.
For personal protection see section 8.
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13).
For disposal see section 13.
Avoid contact with skin and eyes. Avoid inhalation of vapor or mist.
Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic charge.
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
For precautions see section 2.2.
Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Store in cool place.
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Splash contact Material: butyl-rubber
Minimum layer thickness: 0,3 mm Break through time: 60 min
Material tested:Butoject? (KCL 897 / Aldrich Z677647, Size M)
data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Complete suit protecting against chemicals, Flame retardant antistatic protective clothing., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Where risk assessment shows air-purifying respirators are appropriate use a full- face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Surface tension 26,17 mN/m at 25 °C
Relative vapor density
3,94 - (Air = 1.0)
No data available
Stable under recommended storage conditions.
No data available
Heat, flames and sparks.
Strong oxidizing agents, Strong reducing agents, Strong bases
In the event of fire: see section 5
semi-static test EC50 - Daphnia magna (Water flea) - > 90,1 mg/l - 48 h
- 72 h
(OECD Test Guideline 201)
Biodegradability aerobic - Exposure time 28 d
Result: 69 % - Readily biodegradable. (OECD Test Guideline 310)
Ratio BOD/ThBOD 1,77 %
No data available
No data available
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
No data available
Offer surplus and non-recyclable solutions to a licensed disposal company. Waste material
must be disposed of in accordance with the Directive on waste 2008/98/EC as well as other national and local regulations. Leave chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself.
Waste DisposalDissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber. All federal, state, and local environmental regulations must be observed.
Dispose of as unused product.
ADR/RID: 1110 IMDG: 1110 IATA: 1110
ADR/RID: 3 IMDG: 3 IATA: 3
ADR/RID: III IMDG: III IATA: III
ADR/RID: no IMDG Marine pollutant: no IATA: no
No data available
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.