Chemical Safety Data Sheet MSDS / SDS

Lead(II) iodide

Revision Date:2024-10-26Revision Number:1

SECTION 1: Identification of the substance/mixture and of the company/undertaking

Product identifier

  • Product name: Lead(II) iodide
  • CBnumber: CB2771616
  • CAS: 10101-63-0
  • EINECS Number: 233-256-9
  • Synonyms: PbI2,lead iodide

Relevant identified uses of the substance or mixture and uses advised against

  • Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
  • Uses advised against: none

Company Identification

  • Company: Chemicalbook
  • Address: Building 1, Huihuang International, Shangdi 10th Street, Haidian District, Beijing
  • Telephone: 400-158-6606

SECTION 2: Hazards identification

GHS Label elements, including precautionary statements

  • Symbol(GHS)
  • Signal wordDanger
Precautionary statements
P405 Store locked up.
P308+P313 IF exposed or concerned: Get medical advice/attention.
P304+P340 IF INHALED: Remove victim to fresh air and Keep at rest in a position comfortable for breathing.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P201 Obtain special instructions before use.
Hazard statements
H410 Very toxic to aquatic life with long lasting effects
H400 Very toxic to aquatic life
H373 May cause damage to organs through prolonged or repeated exposure
H360 May damage fertility or the unborn child
H332 Harmful if inhaled
H302 Harmful if swallowed

SECTION 3: Composition/information on ingredients

Substance

  • Product name: Lead(II) iodide
  • Synonyms: PbI2,lead iodide
  • CAS: 10101-63-0
  • EC number: 233-256-9
  • MF: I2Pb
  • MW: 461.01

SECTION 4: First aid measures

Description of first aid measures

General advice
Show this material safety data sheet to the doctor in attendance.
If inhaled
After inhalation: fresh air. Call in physician.
In case of skin contact
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.
In case of eye contact
After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
If swallowed
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.

Most important symptoms and effects, both acute and delayed

The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11

Indication of any immediate medical attention and special treatment needed

No data available

SECTION 5: Firefighting measures

Extinguishing media

Suitable extinguishing media
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Unsuitable extinguishing media
For this substance/mixture no limitations of extinguishing agents are given.

Special hazards arising from the substance or mixture

Hydrogen iodide Lead oxides

Not combustible.

Ambient fire may liberate hazardous vapours.

Advice for firefighters

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

Further information

Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.

NFPA 704

2
0
0
HEALTH 2 Intense or continued but not chronic exposure could cause temporary incapacitation or possible residual injury (e.g. diethyl ether, ammonium phosphate, iodine)
FIRE 0 Materials that will not burn under typical fire conditions, including intrinsically noncombustible materials such as concrete, stone, and sand. Materials that will not burn in air when exposed to a temperature of 820 °C (1,500 °F) for a period of 5 minutes.(e.g. Carbon tetrachloride)
REACT 0 Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2)
SPEC. HAZ.

SECTION 6: Accidental release measures

Personal precautions, protective equipment and emergency procedures

Advice for non-emergency personnel: Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.

For personal protection see section 8.

Environmental precautions

Do not let product enter drains.

Methods and materials for containment and cleaning up

Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully. Dispose of properly. Clean up affected area. Avoid generation of dusts.

Reference to other sections

For disposal see section 13.

SECTION 7: Handling and storage

Precautions for safe handling

Advice on safe handling

Work under hood. Do not inhale substance/mixture.

Hygiene measures

Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.

For precautions see section 2.2.

Conditions for safe storage, including any incompatibilities

Storage conditions

Handle under argon.

Tightly closed. Dry. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorized persons.

Air and moisture sensitive. Hygroscopic. Light sensitive. Handle and store under inert gas.

Specific end use(s)

Apart from the uses mentioned in section 1.2 no other specific uses are stipulated

SECTION 8: Exposure controls/personal protection

control parameter

Hazard composition and occupational exposure limits
Does not contain substances with occupational exposure limits.

Exposure controls

Personal protective equipment
Eye/face protection

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Skin protection

This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Full contact

Material: Nitrile rubber

Minimum layer thickness: 0,11 mm Break through time: 480 min

Material tested:KCL 741 Dermatril? L

Splash contact Material: Nitrile rubber

Minimum layer thickness: 0,11 mm Break through time: 480 min

Material tested:KCL 741 Dermatril? L

Body Protection

protective clothing

Respiratory protection

required when dusts are generated.

Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.

Recommended Filter type: Filter type P3

The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.

These measures have to be properly documented.

Control of environmental exposure

Do not let product enter drains.

SECTION 9: Physical and chemical properties

Information on basic physicochemical properties

  • Appearanceyellow Beads
  • OdourNo data available
  • Odour ThresholdNo data available
  • pHNo data available
  • Melting point/freezing pointMelting point/range: 402 °C
  • Initial boiling point and boiling range954 °C at 1.013 hPa
  • Flash pointNot applicable
  • Evaporation rateNo data available
  • Flammability (solid, gas)No data available
  • Upper/lower flammability or explosive limitsNo data available
  • Vapour pressure 1 hPa at 479 °C
  • Vapour density No data available
  • Relative density6.16
  • Water solubilitySoluble in concentrated solutions of alkali iodides and sodium thiosulfate. Insoluble in alcohol and cold hydrochloric acid.
  • Partition coefficient: n-octanol/waterNo data available
  • Autoignition temperatureNo data available
  • Decomposition temperatureNo data available
  • ViscosityViscosity, kinematic: No data available Viscosity, dynamic: No data available
  • Explosive propertiesNo data available
  • Oxidizing propertiesNo data available
  • λmax539nm(neat)(lit.)
  • Solubility Product Constant (Ksp)pKsp: 8.01

Other safety information

No data available

SECTION 10: Stability and reactivity

Reactivity

No data available

Chemical stability

The product is chemically stable under standard ambient conditions (room temperature) .

Possibility of hazardous reactions

No data available

Conditions to avoid

no information available

Incompatible materials

Strong oxidizing agents

Hazardous decomposition products

In the event of fire: see section 5

SECTION 11: Toxicological information

Information on toxicological effects

Acute toxicity
Oral
LC50 Inhalation - 4 h - 1,5 mg/l Dermal
Skin corrosion/irritation
No data available
Serious eye damage/eye irritation
No data available
Respiratory or skin sensitization
No data available
Germ cell mutagenicity
No data available
Carcinogenicity
No data available
Reproductive toxicity
May cause congenital malformation in the fetus. Known human reproductive toxicant
Specific target organ toxicity - single exposure
No data available
Specific target organ toxicity - repeated exposure
May cause damage to organs through prolonged or repeated exposure.
No data available

SECTION 12: Ecological information

Toxicity

No data available

Persistence and degradability

No data available

Bioaccumulative potential

No data available

Mobility in soil

No data available

Results of PBT and vPvB assessment

This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

Other adverse effects

No data available

SECTION 13: Disposal considerations

Waste treatment methods

Product

See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.

Incompatibilities

Lead iodide has weak oxidizing or reducing powers. Redox reactions can however still occur. The majority of compounds in this class are slightly soluble or insoluble in water. If soluble in water, then the solutions are usually neither strongly acidic nor strongly basic. These compounds are not water-reactive. Light sensitive Contact with oxidizers or active metals may cause violent reaction

SECTION 14: Transport information

UN number

ADR/RID: 2291 IMDG: 2291 IATA: 2291

UN proper shipping name

ADR/RID: LEAD COMPOUND, SOLUBLE, N.O.S. (Lead diiodide) IMDG: LEAD COMPOUND, SOLUBLE, N.O.S. (Lead diiodide)

IATA: Lead compound, soluble, n.o.s. (Lead diiodide)

Transport hazard class(es)

ADR/RID: 6.1 IMDG: 6.1 IATA: 6.1

Packaging group

ADR/RID: III IMDG: III IATA: III

Environmental hazards

ADR/RID: yes IMDG Marine pollutant: yes IATA: no

Special precautions for user

No data available

SECTION 15: Regulatory information

Safety, health and environmental regulations/legislation specific for the substance or mixture

Regulations on the Safety Management of Hazardous Chemicals
China Catalog of Hazardous chemicals 2015:Not Listed. website: https://www.mem.gov.cn/
Measures for Environmental Management of New Chemical Substances
New Zealand Inventory of Chemicals (NZIoC):Listed. website: https://www.epa.govt.nz/
Korea Existing Chemicals List (KECL):Listed. website: http://ncis.nier.go.kr
Philippines Inventory of Chemicals and Chemical Substances (PICCS):Listed. website: https://emb.gov.ph/
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC):Listed. website: https://www.mee.gov.cn/
EC Inventory:Listed.
United States Toxic Substances Control Act (TSCA) Inventory:Listed. website: https://www.epa.gov/
European Inventory of Existing Commercial Chemical Substances (EINECS):Listed. website: https://echa.europa.eu/
Vietnam National Chemical Inventory:Listed. website: https://chemicaldata.gov.vn/

SECTION 16: Other information

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple

【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp

【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/

【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en

【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg

【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp

【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm

【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/

【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home

【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/

Disclaimer:

The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.

Recommended Products
Tetrabutylammonium iodide SDS Ammonium iodide SDS Lead(II) iodide SDS Potassium iodide SDS Cuprous iodide SDS Zinc iodide SDS BISMUTH POTASSIUM IODIDE SDS Lithium iodide SDS Propidium iodide SDS Lead SDS